99久久久无码国产精品不卡,99久久久无码国产精品秋霞网,99久久久无码国产精品试看,99久久久无码国产精品性

Shanghai Zhiyue Electric Co., Ltd    021-53080810   a65148373@163.com
China Zhiyue

ZUM1L-800/3N Residual current operated circuit breaker

ZUM1L-800/3N Residual current operated circuit breaker

Rated frequency: 50Hz
Rated residual operating current: 50/75/100/150/200/300/500/800/1000mA,
rated residual non-operating current 0.5I△n: Abrupt leakage action value: ≤50mA Single product only uses four For each gear, please refer to the value on the nameplate.
Rated breaking time: <0.2s/<0.5s can be set to automatically reclose once from 20s to 60s

Read More
ZUM1L-100/3N Residual current operated circuit breaker

ZUM1L-100/3N Residual current operated circuit breaker

Delayed reclosing time: 70% of rated voltage,
undervoltage action value: 120% of rated voltage (can be closed)
, overvoltage action value: action when any phase of ABC three-phase is missing (can be closed);
phase failure protection: functional module The power supply is directly taken from the three-phase power supply of the autonomous loop, which completely avoids the problem of phase loss and residual current protection not working.

Read More
ZUM1-63 100 225 400 630 800 1250 Moulded case circuit breaker

ZUM1-63 100 225 400 630 800 1250 Moulded case circuit breaker

Note*: The neutral pole (N pole) of the four-level product is divided into four types of
A-type N-pole, no overcurrent tripping element is installed, and the N-pole is always on, not combined with other three-level;
B-type N-pole No overcurrent trip element is installed, and the N pole is combined with other three levels (N pole is closed first and then opened);
C-type N pole is installed with overcurrent trip element, and the N pole is combined with other three levels (N The pole is closed first and then opened);
D-type N pole is installed with an overcurrent trip element, and the N pole is always on, and does not open and close together with other three levels;

Read More
ZUM1 Plastic case circuit breaker

ZUM1 Plastic case circuit breaker

1. The upper limit of ambient air temperature is +40℃, the lower limit is -5℃, and the average value of 24h does not exceed +35℃.
2. Altitude: The altitude of the installation site does not exceed 2000m.
3. Relative humidity: the relative humidity of the atmosphere does not exceed 50% when the ambient air temperature is +40℃, and it can have a higher relative humidity at a lower temperature; the monthly average maximum relative humidity of the wettest month is 90%, and the The monthly average minimum temperature of the month is +25°C, taking into account the condensation on the surface of the product due to temperature changes.
4. Pollution degree: Pollution degree is 3

Read More
ZUM1 Intelligent universal circuit breaker

ZUM1 Intelligent universal circuit breaker

1. Ambient temperature: ambient air temperature is -5°C-+40°C (special order must be negotiated with the manufacturer);
2. Altitude: The altitude of the installation site is 2000mm;
3. Pollution degree: Pollution degree is 3;
4. Installation position: it should be installed vertically, with an inclination not exceeding 5°;

Read More
DZ47 Miniature circuit breaker

DZ47 Miniature circuit breaker

1. Altitude: no more than 2000m;
2. Ambient temperature: -5°C~+40°C, the average value of 24h does not exceed 35°C. If it exceeds this range, please consult with the manufacturer;
3. Relative humidity: no more than 50% when the maximum temperature is +40℃, and the maximum relative humidity is 90% (20℃). Special measures must be taken for condensation on the product due to temperature changes;
4. Pollution level: Level 2;

Read More