Reactive power compensation controller

JKW-3SC Three phase common compensation intelligent reactive power compensation controller with dynamic output
  • JKW-3SC Three phase common compensation intelligent reactive power compensation controller with dynamic output

JKW-3SC Three phase common compensation intelligent reactive power compensation controller with dynamic output

Capacitor capacity input function, automatic identification number method for optimized switching.
There is a settable re-investment lock time to ensure that the capacitor has enough discharge time before being turned on.
The output signal can be set to close a certain group or open a certain group of work.
Various parameters are all digitally adjustable, which can be widely applied to different power grid conditions.
Strong anti-interference ability, can directly resist interference pulses from peripheral common mode amplitude 2000V.

Detailed introduction

JKW-3SC Three phase common compensation intelligent reactive power compensation controller with dynamic output

JKW-3SC Three phase common compensation intelligent reactive power compensation controller with dynamic output

Main purpose and scope of application
JKW-3 series intelligent low-voltage reactive power compensation controller (controller for short) is a special equipment for low-voltage power distribution system to compensate reactive power. It is based on the industry standard of the People’s Republic of China JB/T9663 and the power industry standard DL/ T597 design. The sampled physical quantity is reactive power, and the DC level output can directly drive intelligent composite switches and capacitive non-contact switches to switch power capacitors. It has the advantages of beautiful appearance, novel design, multiple functions, good control performance, and high reliability. It is in a leading position among similar domestic products and provides a brand-new equipment for power distribution automation. The words displayed when this series of products are powered on indicate the program version of the product.
This product complies with: industry standard JB/T9663-2013 (our company is the main drafting unit of this standard).

Model and meaning

Working conditions
1. Power supply voltage: the rated value is AC 380V/220V, and the fluctuation cannot exceed ±20%;
2. Ambient temperature: -25°C~55°C;
3. Relative humidity: the maximum relative humidity is 90% (at 20°C) ;
4, altitude: not more than 2000m;
. 5, environmental conditions: no explosion hazard medium flammable, non-corrosive metal gas and damage of an electrically insulating conductive dust;

Main technical parameters
1. Rated current: AC 0~5A;
2. Rated voltage: AC 220V/380V;
3. Contact capacity: dynamic DC12V/50mA per
branch; 4. Current input impedance: ≤0.02Ω;
5. Shell Protection level: IP30;
6. Frequency: 50Hz;
7. Sensitivity: 30mA;
8. Insulation voltage: 690V;

Features
1. Real-time display of network conditions: including reactive power, power factor, secondary current, primary current, system voltage, etc. (by clicking the up and down keys to switch during automatic operation).
2. Automatically identify the polarity of the sampling signal, and there is no concern about the polarity of the wiring.
3. It has the function of power-off memory for setting parameters, and the data will not be lost after power-off.
4. With over-voltage and under-voltage protection functions.
5. With dual input threshold: it is required that the power factor is lower than the input threshold setting value and the reactive power is greater than the minimum set of capacitors before it can be used to effectively prevent switching oscillations.
6. The input and removal delays are separately adjustable, which is more applicable to the power grid.
7. Capacitor capacity input function, automatic identification numbering method for optimized switching.
8. There is a settable re-investment lock time to ensure that the capacitor has enough discharge time before being turned on.
9. The output signal can be set to close a certain group or open a certain group of work.
10. Various parameters are all digitally adjustable, which can be widely applied to different power grid conditions.
11. Strong anti-interference ability, can directly resist interference pulses from peripheral common mode amplitude 2000V.

Factory setting values of various parameters

Code meaning Setting value Adjustable range
P-00 Current polarity recognition method AUTO AUTO automatic/HAND manual
P-01 Power factor input threshold 0.95 0.800~1.000
P-02 Power factor cut off threshold 1 0.900~-.900
P-03 Input delay 5 0.1~100s
P-04 Cut-off delay 5 0.1~100s
P-05 Overvoltage protection 440/245 400~500 / 230~270
P-06 Recast lock time 30 0~240s
P-07 Transformer ratio 500 5~9000
C-01~C-12 Capacitor capacity 5 0~200kvar

Main specifications and models

Product number Hole Size Sampling voltage Signal frequency Number of control groups monitor Total Weight Replace the old model
JKW-3SC-12D 113×113 Line voltage 380V 50/60Hz 1~12 Luminous Digital 0.9kg JKWD15
JKW-3DC-12D 113×113 Phase voltage 220V 50/60Hz 1~12 Luminous Digital 0.9kg JKWD2C
JKW-3SA-16D 139×139 Line voltage 380V 50/60Hz 1~16 Luminous Digital 0.95kg -
JKW-3SA-19D 139×139 Line voltage 380V 50/60Hz 1~19 Luminous Digital 0.95kg -

Wiring schematic diagram

 

Message Feedback

If you have any enquiry about quotation or cooperation,please free to email us ata65148373@163.comor use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.

Get to know Us Better Now!

Share our Product over the Social Networks

Search!

Search across our website

主站蜘蛛池模板: 密山市| 莎车县| 铜山县| 丹棱县| 石景山区| 江城| 楚雄市| 蓬安县| 桦川县| 湘西| 宜城市| 广饶县| 丰原市| 科技| 陵川县| 神木县| 伊春市| 林甸县| 许昌市| 崇左市| 灵武市| 文昌市| 沙坪坝区| 乐昌市| 潜江市| 柳河县| 东平县| 九龙县| 锦屏县| 新乐市| 永安市| 新化县| 海安县| 隆昌县| 建瓯市| 陆良县| 方山县| 全州县| 北流市| 泽库县| 邵武市|