Power supply voltage: 380V ±20%
Signal voltage: AC50V-275V (phase voltage)
signal current AC 0-5.5A (If the sampling current is greater than 5.5A, a power factor display error will occur).
Working frequency: 45e-65Hz.
Undervoltage threshold: 176V
(l) Calculate the switching capacitor capacity based on the fundamental reactive power, which can avoid various forms of switching shocks, and can correctly display the power factor of the grid under harmonics.
(2) The power factor measurement progress is high, and the display range is high. Wide.
(3) Up to 32 loop capacitor groups can be controlled
(4) Shortcut function keyboard, large screen LED display, Chinese operation, friendly man-machine interface is still convenient
(1) The altitude is not higher than 2500 meters.
(2) Ambient temperature: -20°C to +45°C.
(3) The air humidity does not exceed 50% at 40°C, and does not exceed 90% at 20°C.
(4) There is no corrosive gas, no conductive dust, and no flammable and explosive media in the surrounding environment.
(5) There is no severe vibration at the installation site.
(1) Calculate the switching capacitor capacity based on the fundamental reactive power, which can avoid various forms of switching oscillations, and can correctly display the power factor of the grid in the presence of harmonics.
(2) The power factor measurement accuracy is high, and the display range is wide.
(3) Up to 32 loop capacitor groups can be controlled.
(4) Shortcut function keyboard, large-screen LCD display, Chinese operation, friendly man-machine interface and convenient operation.
(1) Calculate the switching capacitor capacity based on the fundamental reactive power, which can avoid various forms of switching oscillations, and can correctly display the power factor of the grid in the presence of harmonics.
(2) The power factor measurement accuracy is high, and the display range is wide.
(3) There are 12 kinds of capacitor capacity coding methods for users to choose.
(4) Reprogrammable compensation scheme and output circuit.
Power supply voltage: 220V (1-2 feet) or 380V (1-3 feet), with two power input ports of different voltage levels, 380V power supply is recommended if possible.
Signal voltage: AC50V-275V (phase voltage).
Signal current: AC0-5.5A.
Working frequency: 45-65Hz. Undervoltage threshold: 176V.
1. Altitude: no higher than 2500 meters
2. Ambient temperature: -25°C~+50°C;
3. Air humidity: no more than 50% at 40°C and no more than 90% at 20°C;
4. Surrounding environment: No corrosive gas, no conductive dust, no flammable and explosive media;
5. No severe vibration at the installation site;